Solution Of Diesel Engine Air Intake Failure

Diesel engine intake and exhaust failure causes and solutions:

1, with gears installed wrong, adjust the gears.

2, into the exhaust valve did not run well, so that the exhaust valve to run, if it is a short fault after a period of time running no problem.

3, the valve gap adjustment is wrong, re-adjust the valve clearance so that the diesel engine out of the exhaust properly.

If this is the operation of the diesel engine (that is not overhaul) this phenomenon, you should first check the valve clearance, and then check that the exhaust valve is a serious leak, and finally check the timing gear will not fall teeth (gear box Abnormal sound).